Validation of the Pre-vent™ Mask for Maximal Metabolic Exercise Testing
Ong, Michelle D.; Vallejo, Alberto F.; Jensky, Nicole E.; Schroeder, E. Todd,
University of Southern California, Los Angeles, CA
(Sponsor: Steve A. Hawkins, FACSM)

The standard mouthpiece is an important component for metabolic exercise testing. However, the mouthpiece can fatigue jaw muscles and cause dryness in the throat; thus, resting in discomfort to its users. The Pre-Vent™ Mask is an alternative, which eliminates these discomforting factors, especially during maximal effort.

Purpose:
To validate the use of the Pre-Vent™ Mask versus the mouthpiece during maximal treadmill exercise testing.

Methods:
Data were gathered on 19 subjects [11 women (24.7±3.2 years; 64.5±8.1kg) and 8 men (30.9±7.3 years; 81.1±9.0 kg)] who visited the laboratory on two different occasions. During each visit, the subjects performed a maximal treadmill exercise test randomized to either the mouthpiece or the Pre-Vent™ Mask. A modified Bruce protocol was used which initially started at 2.5 m.p.h. and 0% grade with increments of 0.5 m.p.h. and 2% grade every two minutes. Gas was collected using the Medical Graphics Cardio II gas analysis module (BreezeSuite software version 6.0 A). Heart rate was determined by using 3-lead ECG (Cardio Control Workstation version 1.3.1). Values at maximal levels were analyzed by paired t-test (mouthpiece versus mask) using the 0.05 level of significance.

Results:
Maximal relative volume of oxygen consumption (VO2) (ml/kg/min), absolute VO2 (Mask: 3.7±1.0, Pre-Vent™ 3.6±0.8 L/min) volume of carbon dioxide expired (VCO2) (Mask: 4.3±1.2, Pre-Vent™ 4.1±0.9 L/min), respiratory exchange ratio (RER), ventilation volume (VE; L/min), and heart rate (HR; bpm) were not significantly different between the mouthpiece and the Pre-Vent™ Mask.

Conclusion:
The Pre-Vent™ Mask is a valid device for maximal metabolic exercise treadmill testing, as well as at submaximal levels. The Pre-Vent™ Mask may be a more comfortable alternative to the tradition mouthpiece.

http://www.acsm-msse.org/

° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° °
Ong, Michelle D.; Vallejo, Alberto F.; Jensky, Nicole E.; Schroeder, E. Todd. Medicine & Science in Sports & Exercise. Vol.375(5), Supplement 1, p S230. May 2005.

"Validation of the Pre-vent™ Mask for Maximal Metabolic Exercise Testing": 1209, Board #64 3:30 PM – 5:00 PM
[D-22: Free Communication/Poster – Clinical Exercise Testing: THURSDAY, JUNE 2, 2005 2:00 PM – 5:00 PM ROOM: Ryman C2]


© 2005 The American College of Sports Medicine
Published by Lippincott Williams & Wilkins
graphic
FIND A
NEW LEAF SITE NEAR YOU


enter your zip
code:


within:


graphic
NEW LEAF
QUICK LINKS

orange bullet Garmin
orange bullet eNewLeaf.com
orange bullet ENERGYsmart™
orange bullet New Leaf
   web store
NEW LEAF INFORMATION
> contact us
> company info
> news release
> product release
graphic graphic
graphic graphic
graphic © 2008 Angeion Corporation graphic
New Leaf Active Metabolic Training home New Leaf Active Metabolic Training home